{"id":6880,"date":"2026-05-19T19:28:37","date_gmt":"2026-05-19T23:28:37","guid":{"rendered":"https:\/\/internationalprocessplants.com\/?p=6880"},"modified":"2026-06-16T14:22:02","modified_gmt":"2026-06-16T18:22:02","slug":"%e5%8f%8d%e5%ba%94%e5%a0%86%e5%8e%8b%e5%8a%9b%e7%ad%89%e7%ba%a7%e5%92%8casme%e5%90%88%e8%a7%84%e6%80%a7","status":"publish","type":"post","link":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/","title":{"rendered":"\u4ec0\u4e48\u662f\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\uff1f\u5b83\u4e0eASME\u5408\u89c4\u6027\u6709\u4f55\u5173\u7cfb\uff1f"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">\u53cd\u5e94\u5806\u538b\u529b\u989d\u5b9a\u503c\u662f\u6307\u5bb9\u5668\u5728\u7279\u5b9a\u6e29\u5ea6\u4e0b\u80fd\u591f\u5b89\u5168\u627f\u53d7\u7684\u6700\u5927\u5185\u90e8\u538b\u529b\uff0c\u8be5\u538b\u529b\u901a\u8fc7\u5de5\u7a0b\u8ba1\u7b97\u786e\u5b9a\uff0c\u5e76\u53d7\u7f8e\u56fd\u673a\u68b0\u5de5\u7a0b\u5e08\u534f\u4f1a\u9505\u7089\u53ca\u538b\u529b\u5bb9\u5668\u89c4\u8303\uff08BPVC\uff09\u7b2c\u516b\u5377\u7684\u7ea6\u675f\u3002\u7b26\u5408\u7f8e\u56fd\u673a\u68b0\u5de5\u7a0b\u5e08\u534f\u4f1a\uff08ASME\uff09\u6807\u51c6\u53ef\u786e\u8ba4\u53cd\u5e94\u5806\u7684\u8bbe\u8ba1\u3001\u5236\u9020\u3001\u6d4b\u8bd5\u548c\u6587\u4ef6\u7b26\u5408\u8fd9\u4e9b\u89c4\u8303\u8981\u6c42\uff0c\u4ece\u800c\u4fdd\u8bc1\u5176\u5408\u6cd5\u8fd0\u884c\u548c\u4fdd\u9669\u6709\u6548\u6027\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u672c\u6307\u5357\u6db5\u76d6\u538b\u529b\u7b49\u7ea7\u7684\u5b89\u5168\u6027\u548c\u6027\u80fd\u5f71\u54cd\u3001ASME \u89c4\u8303\u548c\u8ba4\u8bc1\u6d41\u7a0b\u3001\u5e38\u89c1\u7684\u5408\u89c4\u6027\u6311\u6218\u3001\u6750\u6599\u9009\u62e9\u56e0\u7d20\u4ee5\u53ca\u8f6c\u552e\u548c\u91cd\u65b0\u90e8\u7f72\u8003\u8651\u56e0\u7d20\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u538b\u529b\u7b49\u7ea7\u901a\u8fc7\u5b9a\u4e49\u5b89\u5168\u64cd\u4f5c\u8303\u56f4\u6765\u4fdd\u62a4\u4eba\u5458\u548c\u8bbe\u5907\uff1b\u8d85\u8fc7\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u4f1a\u6d88\u9664\u5de5\u7a0b\u5b89\u5168\u88d5\u5ea6\uff0c\u5e76\u53ef\u80fd\u5bfc\u81f4\u707e\u96be\u6027\u7684\u5bb9\u5668\u6545\u969c\u6216\u4fdd\u9669\u5931\u6548\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">ASME BPVC \u7b2c VIII \u5377\u7b2c 1 \u90e8\u5206\u89c4\u5b9a\u6781\u9650\u6297\u62c9\u5f3a\u5ea6\u9700\u91c7\u7528 3.5 \u500d\u7684\u5b89\u5168\u7cfb\u6570\uff0c\u800c UG-99 \u6761\u6b3e\u5219\u5f3a\u5236\u8981\u6c42\u6240\u6709\u8239\u8236\u5728\u83b7\u5f97\u89c4\u8303\u8ba4\u8bc1\u524d\uff0c\u5fc5\u987b\u8fdb\u884c\u81f3\u5c11 1.3 \u500d\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u7684\u6c34\u538b\u8bd5\u9a8c\u3002\u6388\u6743\u68c0\u9a8c\u5458\u8d1f\u8d23\u6838\u5b9e\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\uff0c\u800c\u56fd\u5bb6\u8ba4\u8bc1\u59d4\u5458\u4f1a\u7684\u6ce8\u518c\u5219\u786e\u8ba4\u8239\u8236\u7ed3\u6784\u7b26\u5408\u89c4\u8303\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5f53\u7f3a\u5c11\u6587\u4ef6\u3001\u710a\u63a5\u8bb0\u5f55\u4e0d\u5b8c\u6574\u6216\u5bb9\u5668\u7684\u89c4\u8303\u72b6\u6001\u672a\u77e5\u65f6\uff0c\u5c06\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u4e0e ASME \u8981\u6c42\u8fdb\u884c\u5339\u914d\u5c31\u53d8\u5f97\u5341\u5206\u590d\u6742\u3002\u5de5\u7a0b\u8bc4\u4f30\u3001\u9002\u7528\u6027\u8bc4\u4f30\u548c R \u94a2\u5370\u4fee\u590d\u662f\u89e3\u51b3\u6b64\u7c7b\u95ee\u9898\u7684\u9014\u5f84\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u6750\u6599\u7279\u6027\u76f4\u63a5\u51b3\u5b9a\u4e86\u53ef\u8fbe\u5230\u7684\u538b\u529b\u7b49\u7ea7\uff1b\u50cf Hastelloy C-276 \u548c 316L \u4e0d\u9508\u94a2\u8fd9\u6837\u7684\u5408\u91d1\u6bd4\u642a\u73bb\u7483\u7ed3\u6784\u80fd\u627f\u53d7\u66f4\u9ad8\u7684\u5141\u8bb8\u5e94\u529b\uff0c\u800c\u8150\u8680\u88d5\u91cf\u8981\u6c42\u5219\u56e0\u4f7f\u7528\u4e25\u82db\u7a0b\u5ea6\u800c\u5f02\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5bf9\u4e8e\u4e8c\u624b\u6216\u7ffb\u65b0\u53cd\u5e94\u5806\uff0c\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u6587\u4ef6\uff08\u5305\u62ec U-1 \u8868\u683c\u3001WPS\/PQR \u8bb0\u5f55\u548c\u68c0\u67e5\u5386\u53f2\uff09\u5bf9\u4e8e\u5408\u6cd5\u8f6c\u8ba9\u3001\u8de8\u53f8\u6cd5\u7ba1\u8f96\u533a\u7684\u91cd\u65b0\u90e8\u7f72\u4ee5\u53ca\u7b26\u5408\u56fd\u9645\u7b49\u6548\u6807\u51c6\uff08\u4f8b\u5982\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU\u3001EN 13445 \u548c\u82f1\u56fd 2000 \u5e74\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6cd5\u89c4\uff09\u81f3\u5173\u91cd\u8981\u3002.<\/span><\/p>\n<h2><b>\u4e3a\u4ec0\u4e48\u538b\u529b\u7b49\u7ea7\u5bf9\u53cd\u5e94\u5806\u7684\u5b89\u5168\u6027\u548c\u6027\u80fd\u81f3\u5173\u91cd\u8981\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u538b\u529b\u7b49\u7ea7\u5bf9\u4e8e\u53cd\u5e94\u5806\u7684\u5b89\u5168\u6027\u548c\u6027\u80fd\u81f3\u5173\u91cd\u8981\uff0c\u56e0\u4e3a\u5b83\u5b9a\u4e49\u4e86\u5bb9\u5668\u5728\u8fd0\u884c\u671f\u95f4\u80fd\u591f\u5b89\u5168\u627f\u53d7\u7684\u6700\u5927\u5185\u90e8\u538b\u529b\u3002\u8d85\u8fc7\u8fd9\u4e9b\u9650\u5236\u503c\u4f1a\u5bfc\u81f4\u707e\u96be\u6027\u6545\u969c\u3001\u4eba\u5458\u4f24\u4ea1\u548c\u8fdd\u53cd\u6cd5\u89c4\u3002\u4ee5\u4e0b\u7ae0\u8282\u5c06\u89e3\u91ca\u538b\u529b\u7b49\u7ea7\u7684\u786e\u5b9a\u65b9\u6cd5\u4ee5\u53ca\u53cd\u5e94\u5806\u5728\u8d85\u51fa\u5176\u6307\u5b9a\u9650\u503c\u8fd0\u884c\u65f6\u4f1a\u53d1\u751f\u4ec0\u4e48\u60c5\u51b5\u3002.<\/span><\/p>\n<h3><b>\u53cd\u5e94\u5806\u538b\u529b\u989d\u5b9a\u503c\u662f\u5982\u4f55\u786e\u5b9a\u7684\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u53cd\u5e94\u5806\u538b\u529b\u989d\u5b9a\u503c\u662f\u901a\u8fc7\u5de5\u7a0b\u8ba1\u7b97\u786e\u5b9a\u7684\uff0c\u8ba1\u7b97\u8003\u8651\u4e86\u6750\u6599\u5f3a\u5ea6\u3001\u58c1\u539a\u3001\u8fd0\u884c\u6e29\u5ea6\u548c\u8150\u8680\u88d5\u91cf\u3002\u5de5\u7a0b\u5e08\u5c06\u6b63\u5e38\u8fd0\u884c\u671f\u95f4\u9884\u671f\u7684\u6700\u4e25\u82db\u7684\u538b\u529b\u548c\u6e29\u5ea6\u7ec4\u5408\u6761\u4ef6\u8bbe\u5b9a\u4e3a\u8bbe\u8ba1\u538b\u529b\uff0c\u7136\u540e\u5e94\u7528\u89c4\u8303\u89c4\u5b9a\u7684\u5b89\u5168\u7cfb\u6570\u5f97\u51fa\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b\uff08MAWP\uff09\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u538b\u529b\u7b49\u7ea7\u5224\u5b9a\u4e0d\u5f53\u7684\u540e\u679c\u5341\u5206\u4e25\u91cd\u3002\u6839\u636e\u2026\u2026 <\/span><i><span style=\"font-weight: 400;\">\u5316\u5b66\u5de5\u827a\u5b89\u5168<\/span><\/i><span style=\"font-weight: 400;\">, \u4e00\u6b21\u4e25\u91cd\u7684\u8fc7\u538b\u4e8b\u6545\u5bfc\u81f4\u4e00\u5ea7\u9ad8\u5ea6\u5de5\u7a0b\u5316\u7684\u954d\u5305\u58f3\u53cd\u5e94\u5806\u53d7\u635f\uff0c\u635f\u5931\u8d85\u8fc7$500,000\u3002\u8bf8\u5982ASME\u7b2c\u516b\u5377\u3001\u538b\u529b\u8bbe\u5907\u6307\u4ee4(PED) 2014\/68\/EU\u4ee5\u53ca\u82f1\u56fd2000\u5e74\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6761\u4f8b(PSSR)\u7b49\u76d1\u7ba1\u6846\u67b6\u5747\u89c4\u5b9a\u4e86\u8ba1\u7b97\u548c\u9a8c\u8bc1\u8fd9\u4e9b\u989d\u5b9a\u503c\u7684\u5177\u4f53\u65b9\u6cd5\u3002.<\/span><\/p>\n<h3><b>\u53cd\u5e94\u5806\u5728\u8d85\u51fa\u989d\u5b9a\u538b\u529b\u8303\u56f4\u8fd0\u884c\u4f1a\u5e26\u6765\u54ea\u4e9b\u98ce\u9669\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u53cd\u5e94\u5806\u5728\u989d\u5b9a\u538b\u529b\u8303\u56f4\u5916\u8fd0\u884c\u6240\u5e26\u6765\u7684\u98ce\u9669\u5305\u62ec\u5bb9\u5668\u7834\u88c2\u3001\u5371\u9669\u7269\u8d28\u4e0d\u53d7\u63a7\u5236\u5730\u6cc4\u6f0f\u3001\u4eba\u5458\u4f24\u4ea1\u4ee5\u53ca\u4fdd\u9669\u5931\u6548\u3002\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b\uff08MAWP\uff09\u662f\u6307\u5728\u7279\u5b9a\u6e29\u5ea6\u4e0b\uff0c\u5bb9\u5668\u5728\u6b63\u5e38\u8fd0\u884c\u4f4d\u7f6e\u9876\u90e8\u5141\u8bb8\u7684\u6700\u5927\u538b\u529b\uff1b\u8d85\u8fc7\u6b64\u9608\u503c\u5c06\u4f7f\u8bbe\u8ba1\u7684\u5b89\u5168\u88d5\u5ea6\u5931\u6548\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u8d85\u8fc7\u989d\u5b9a\u538b\u529b\u7684\u4e3b\u8981\u540e\u679c\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u5bb9\u5668\u56e0\u5e94\u529b\u8d85\u8fc7\u6750\u6599\u5c48\u670d\u5f3a\u5ea6\u800c\u53d1\u751f\u707e\u96be\u6027\u5931\u6548\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6cc4\u6f0f\u5bfc\u81f4\u6709\u6bd2\u6216\u6613\u71c3\u5de5\u827a\u4ecb\u8d28\u9038\u51fa\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u76d1\u7ba1\u6267\u6cd5\u884c\u52a8\u548c\u8bbe\u65bd\u5173\u95ed\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u56e0\u4e0d\u7b26\u5408 ASME \u6216 EN \u6807\u51c6\u800c\u5931\u6548\u7684\u5de5\u4e1a\u4fdd\u9669\u5355\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u5bf9\u4e8e\u8bc4\u4f30\u65b0\u7684\u5269\u4f59\u548c\u4f18\u8d28\u4e8c\u624b\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u7684\u91c7\u8d2d\u5de5\u7a0b\u5e08\u6765\u8bf4\uff0c\u5728\u8c03\u8bd5\u4e4b\u524d\uff0c\u9a8c\u8bc1\u94ed\u724c\u4e0a\u7684\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u662f\u5426\u4e0e\u9884\u671f\u7684\u5de5\u827a\u6761\u4ef6\u76f8\u7b26\u662f\u4e0d\u53ef\u534f\u5546\u7684\u7b2c\u4e00\u6b65\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u4e86\u89e3\u8fd9\u4e9b\u5b89\u5168\u9690\u60a3\u662f\u9009\u62e9\u6b63\u786e\u7684 ASME \u89c4\u8303\u548c\u6807\u51c6\u7684\u57fa\u7840\u3002.<\/span><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-6981 size-large\" src=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-1024x572.jpg\" alt=\"\u4e00\u540d\u5de5\u4eba\u6307\u7740\u4e0d\u9508\u94a2\u5de5\u4e1a\u5bb9\u5668\u4e0a\u7684\u94ed\u724c\u7684\u7279\u5199\u955c\u5934\u3002.\" width=\"1024\" height=\"572\" srcset=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-18x10.jpg 18w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-200x112.jpg 200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-300x167.jpg 300w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-400x223.jpg 400w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-600x335.jpg 600w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-768x429.jpg 768w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-800x447.jpg 800w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-1024x572.jpg 1024w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification-1200x670.jpg 1200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-nameplate-inspection-asme-certification.jpg 1376w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h2><b>\u53cd\u5e94\u5806\u538b\u529b\u5bb9\u5668\u7684\u5173\u952eASME\u89c4\u8303\u548c\u6807\u51c6\u6709\u54ea\u4e9b\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u53cd\u5e94\u5806\u538b\u529b\u5bb9\u5668\u7684\u5173\u952eASME\u89c4\u8303\u548c\u6807\u51c6\u4ee5ASME BPVC\u7b2c\u516b\u5377\u4e3a\u6838\u5fc3\uff0c\u8be5\u5377\u89c4\u5b9a\u4e86\u8bbe\u8ba1\u3001\u5236\u9020\u548c\u6d4b\u8bd5\u8981\u6c42\u3002\u4ee5\u4e0b\u5404\u5c0f\u8282\u5c06\u4ecb\u7ecdBPVC\u5982\u4f55\u5e94\u7528\u4e8e\u53cd\u5e94\u5806\uff0c\u4ee5\u53ca\u54ea\u4e9b\u5177\u4f53\u89c4\u8303\u7ae0\u8282\u6700\u4e3a\u76f8\u5173\u3002.<\/span><\/p>\n<h3><b>ASME\u9505\u7089\u53ca\u538b\u529b\u5bb9\u5668\u89c4\u8303\uff08BPVC\uff09\u5982\u4f55\u5e94\u7528\u4e8e\u53cd\u5e94\u5806\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">ASME\u9505\u7089\u53ca\u538b\u529b\u5bb9\u5668\u89c4\u8303\uff08BPVC\uff09\u9002\u7528\u4e8e\u53cd\u5e94\u5806\uff0c\u5b83\u89c4\u5b9a\u4e86\u8bbe\u8ba1\u538b\u529b\u3001\u5236\u9020\u8d28\u91cf\u548c\u6c34\u538b\u8bd5\u9a8c\u7684\u5f3a\u5236\u6027\u89c4\u5219\uff0c\u6240\u6709\u538b\u529b\u5bb9\u5668\u5728\u83b7\u5f97\u89c4\u8303\u8ba4\u8bc1\u4e4b\u524d\u90fd\u5fc5\u987b\u6ee1\u8db3\u8fd9\u4e9b\u89c4\u5219\u3002\u6839\u636eASME BPVC\u7b2c\u516b\u5377\u7b2c\u4e00\u5206\u518c\uff0c\u6807\u51c6\u5b89\u5168\u7cfb\u6570\u4e3a3.5\uff0c\u8fd9\u610f\u5473\u7740\u5141\u8bb8\u5e94\u529b\u7b49\u4e8e\u6781\u9650\u6297\u62c9\u5f3a\u5ea6\u9664\u4ee53.5\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5728\u8fdb\u884c\u89c4\u8303\u8ba4\u8bc1\u4e4b\u524d\uff0cASME UG-99 \u6761\u6b3e\u8981\u6c42\u6240\u6709\u5bb9\u5668\u5fc5\u987b\u8fdb\u884c\u6c34\u538b\u8bd5\u9a8c\uff0c\u6c34\u538b\u81f3\u5c11\u4e3a\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u7684 1.3 \u500d\uff0c\u5e76\u6839\u636e\u8bd5\u9a8c\u6e29\u5ea6\u4e0e\u8bbe\u8ba1\u6e29\u5ea6\u4e4b\u95f4\u7684\u5e94\u529b\u6bd4\u8fdb\u884c\u4fee\u6b63\u3002\u7ecf\u6388\u6743\u7684\u68c0\u9a8c\u5458\u5c06\u6838\u5b9e\u5236\u9020\u5546\u7684\u6570\u636e\u62a5\u544a\uff08\u591a\u8154\u5bb9\u5668\u4f7f\u7528 U-1 \u8868\u683c\uff0c\u5355\u8154\u5bb9\u5668\u4f7f\u7528 U-1A \u8868\u683c\uff09\u3002\u56fd\u5bb6\u9505\u7089\u68c0\u9a8c\u59d4\u5458\u4f1a\u7684\u6ce8\u518c\u786e\u8ba4\u8be5\u5bb9\u5668\u7684\u5efa\u9020\u7b26\u5408 ASME \u89c4\u8303\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u4e0d\u7b26\u5408ASME\u6216EN\u7b49\u516c\u8ba4\u89c4\u8303\u53ef\u80fd\u4f1a\u5bfc\u81f4\u5de5\u4e1a\u4fdd\u9669\u5728\u4e8b\u6545\u53d1\u751f\u65f6\u5931\u6548\u3002\u5bf9\u4e8e\u8bc4\u4f30\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u7684\u91c7\u8d2d\u5de5\u7a0b\u5e08\u800c\u8a00\uff0c\u7ecf\u6838\u5b9e\u7684BPVC\u5408\u89c4\u6027\u5e76\u975e\u53ef\u6709\u53ef\u65e0\uff0c\u800c\u662f\u4fdd\u969c\u4eba\u5458\u5b89\u5168\u548c\u8fd0\u884c\u8fde\u7eed\u6027\u7684\u57fa\u672c\u8981\u6c42\u3002.<\/span><\/p>\n<h3><b>\u4e0e\u538b\u529b\u5bb9\u5668\u53cd\u5e94\u5668\u76f8\u5173\u7684ASME\u89c4\u8303\u4e3b\u8981\u7ae0\u8282\u6709\u54ea\u4e9b\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u4e0e\u538b\u529b\u5bb9\u5668\u53cd\u5e94\u5668\u76f8\u5173\u7684ASME\u4e3b\u8981\u89c4\u8303\u7ae0\u8282\u6709\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u7b2c\u516b\u7ae0\uff0c\u7b2c\u4e00\u8282<\/b><span style=\"font-weight: 400;\"> \u89c4\u5b9a\u4e86\u538b\u529b\u5bb9\u5668\u7684\u5efa\u9020\u89c4\u5219\uff0c\u6db5\u76d6\u8bbe\u8ba1\u3001\u6750\u6599\u3001\u5236\u9020\u548c\u68c0\u9a8c\u8981\u6c42\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u7b2c\u516b\u7ae0\u7b2c\u4e8c\u8282<\/b><span style=\"font-weight: 400;\"> \u63d0\u4f9b\u5177\u6709\u66f4\u9ad8\u5141\u8bb8\u5e94\u529b\u7684\u66ff\u4ee3\u89c4\u5219\uff0c\u5141\u8bb8\u5728\u8fdb\u884c\u66f4\u4e25\u683c\u7684\u5206\u6790\u548c\u6d4b\u8bd5\u65f6\u4f7f\u7528\u66f4\u8584\u7684\u58c1\u539a\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u7b2c\u4e5d\u8282<\/b><span style=\"font-weight: 400;\"> \u5bf9\u710a\u63a5\u548c\u948e\u710a\u8d44\u683c\u8fdb\u884c\u89c4\u5b9a\uff0c\u8981\u6c42\u5236\u5b9a\u4e66\u9762\u710a\u63a5\u5de5\u827a\u89c4\u7a0b (WPS) \u548c\u5de5\u827a\u8bc4\u5b9a\u8bb0\u5f55 (PQR)\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u7b2c\u4e94\u90e8\u5206<\/b><span style=\"font-weight: 400;\"> \u6db5\u76d6\u7528\u4e8e\u9a8c\u8bc1\u710a\u7f1d\u548c\u6750\u6599\u5b8c\u6574\u6027\u7684\u65e0\u635f\u68c0\u6d4b\u65b9\u6cd5\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>\u7b2c\u4e8c\u90e8\u5206<\/b><span style=\"font-weight: 400;\"> \u89c4\u5b9a\u4e86\u5141\u8bb8\u4f7f\u7528\u7684\u6750\u6599\u3001\u5176\u6027\u80fd\u4ee5\u53ca\u5728\u4e0d\u540c\u6e29\u5ea6\u4e0b\u7684\u5141\u8bb8\u5e94\u529b\u503c\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u56fd\u9645\u4e0a\u4e0e\u4e4b\u5bf9\u5e94\u7684\u6807\u51c6\u5305\u62ec\u6b27\u76df\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU\u3001EN 13445\u3001CE \u6807\u5fd7\u548c\u82f1\u56fd UKCA \u6807\u5fd7\u3002\u636e IMARC \u96c6\u56e2\u9884\u6d4b\uff0c2025 \u5e74\u5168\u7403\u538b\u529b\u5bb9\u5668\u5e02\u573a\u89c4\u6a21\u4e3a 263 \u4ebf\u7f8e\u5143\uff0c\u9884\u8ba1\u5230 2034 \u5e74\u5c06\u8fbe\u5230 359 \u4ebf\u7f8e\u5143\uff0c\u8fd9\u53cd\u6620\u51fa\u5168\u7403\u5bf9\u7b26\u5408\u89c4\u8303\u7684\u53cd\u5e94\u5806\u538b\u529b\u5bb9\u5668\u7684\u6301\u7eed\u9700\u6c42\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u4e86\u89e3\u54ea\u4e9b\u90e8\u5206\u9002\u7528\u6709\u52a9\u4e8e\u91c7\u8d2d\u56e2\u961f\u5728\u91c7\u8d2d\u65b0\u7684\u5269\u4f59\u8bbe\u5907\u6216\u4f18\u8d28\u4e8c\u624b\u8bbe\u5907\u4e4b\u524d\uff0c\u6838\u5b9e\u6587\u4ef6\u5305\u662f\u5426\u5b8c\u6574\u3002.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-6983 size-large\" src=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-1024x572.jpg\" alt=\"\u5de5\u7a0b\u5e08\u5728\u6280\u672f\u529e\u516c\u5ba4\u91cc\u7528\u653e\u5927\u955c\u67e5\u770b\u5de5\u4e1a\u8239\u8236\u56fe\u7eb8\u548c\u68c0\u9a8c\u6587\u4ef6\u3002.\" width=\"1024\" height=\"572\" srcset=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-18x10.jpg 18w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-200x112.jpg 200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-300x167.jpg 300w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-400x223.jpg 400w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-600x335.jpg 600w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-768x429.jpg 768w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-800x447.jpg 800w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-1024x572.jpg 1024w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation-1200x670.jpg 1200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/engineer-reviewing-asme-pressure-vessel-technical-documentation.jpg 1376w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h2><b>\u5236\u9020\u5546\u548c\u8fd0\u8425\u5546\u5982\u4f55\u786e\u4fdd\u53cd\u5e94\u5806\u7b26\u5408ASME\u6807\u51c6\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u5236\u9020\u5546\u548c\u8fd0\u8425\u5546\u901a\u8fc7\u4e00\u5957\u7ed3\u6784\u5316\u7684\u8ba4\u8bc1\u6d41\u7a0b\u6765\u786e\u4fdd\u53cd\u5e94\u5806\u7b26\u5408ASME\u6807\u51c6\uff0c\u8be5\u6d41\u7a0b\u5305\u62ec\u6587\u4ef6\u7f16\u5236\u3001\u68c0\u9a8c\u3001\u6c34\u538b\u8bd5\u9a8c\u548c\u94a2\u5370\u9a8c\u8bc1\u3002\u65b0\u5236\u9020\u7684\u53cd\u5e94\u5806\u4e0e\u4e8c\u624b\u6216\u7ffb\u65b0\u53cd\u5e94\u5806\u7684\u8ba4\u8bc1\u6b65\u9aa4\u6709\u6240\u4e0d\u540c\u3002.<\/span><\/p>\n<h3><b>\u538b\u529b\u5bb9\u5668ASME\u8ba4\u8bc1\u5305\u542b\u54ea\u4e9b\u6b65\u9aa4\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u538b\u529b\u5bb9\u5668\u7684ASME\u8ba4\u8bc1\u6b65\u9aa4\u5305\u62ec\u8bbe\u8ba1\u5ba1\u67e5\u3001\u6750\u6599\u9a8c\u8bc1\u3001\u710a\u63a5\u9274\u5b9a\u3001\u5236\u9020\u68c0\u9a8c\u3001\u6c34\u538b\u8bd5\u9a8c\u548c\u6700\u7ec8\u6587\u4ef6\u7f16\u5236\u3002\u6bcf\u4e2a\u6b65\u9aa4\u90fd\u9700\u8981\u7ecf\u6388\u6743\u68c0\u9a8c\u5458\u76d1\u7763\uff0c\u5bb9\u5668\u624d\u80fd\u83b7\u5f97ASME\u8ba4\u8bc1\u5370\u7ae0\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5173\u952e\u8ba4\u8bc1\u6b65\u9aa4\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6309\u7167 ASME \u7b2c IX \u90e8\u5206\u7684\u8981\u6c42\uff0c\u7f16\u5236\u4e66\u9762\u710a\u63a5\u5de5\u827a\u89c4\u7a0b (WPS) \u548c\u5de5\u827a\u8bc4\u5b9a\u8bb0\u5f55 (PQR)\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u5728\u6388\u6743\u68c0\u9a8c\u5458\u7684\u76d1\u7763\u4e0b\uff0c\u4e8e\u89c4\u5b9a\u7684\u5173\u952e\u8282\u70b9\u5b8c\u6210\u5236\u9020\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6839\u636e UG-99 \u8fdb\u884c\u6c34\u538b\u8bd5\u9a8c\uff0c\u6700\u4f4e\u9650\u5ea6\u4e3a MAWP \u7684 1.3 \u500d\uff0c\u5e76\u6839\u636e\u6700\u4f4e\u5e94\u529b\u6bd4\u8fdb\u884c\u4fee\u6b63\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u63d0\u4ea4\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\uff08\u591a\u8154\u5bb9\u5668\u4f7f\u7528 U-1 \u8868\u683c\uff0c\u5355\u8154\u5bb9\u5668\u4f7f\u7528 U-1A \u8868\u683c\uff09\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u5728\u94ed\u724c\u4e0a\u8d34\u4e0a\u56fd\u5bb6\u59d4\u5458\u4f1a\u6ce8\u518c\u53f7\u548cNB\u6807\u5fd7\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u636e Boardman \u516c\u53f8\u79f0\uff0cU-1 \u8868\u683c\u662f\u538b\u529b\u5bb9\u5668\u7684\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\uff0c\u8bb0\u5f55\u4e86\u4ece\u8bbe\u8ba1\u538b\u529b\u5230\u6750\u6599\u53ef\u8ffd\u6eaf\u6027\u7684\u6bcf\u4e00\u4e2a\u53c2\u6570\u3002.<\/span><\/p>\n<h3><b>ASME\u94a2\u5370\u9a8c\u8bc1\u5982\u4f55\u5e94\u7528\u4e8e\u4e8c\u624b\u6216\u7ffb\u65b0\u53cd\u5e94\u5806\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u5bf9\u4e8c\u624b\u6216\u7ffb\u65b0\u53cd\u5e94\u5806\u8fdb\u884cASME\u94a2\u5370\u9a8c\u8bc1\uff0c\u9700\u6838\u5b9e\u539f\u59cb\u8ba4\u8bc1\u8bb0\u5f55\uff0c\u9a8c\u8bc1\u5f53\u524d\u53cd\u5e94\u5806\u5bb9\u5668\u7684\u5b8c\u6574\u6027\uff0c\u5e76\u786e\u4fdd\u6240\u6709\u7ef4\u4fee\u6216\u6539\u9020\u5747\u7b26\u5408\u7f8e\u56fd\u56fd\u5bb6\u6838\u5b89\u5168\u59d4\u5458\u4f1a\u68c0\u9a8c\u89c4\u8303\uff08NBIC\uff09\u3002\u6839\u636e\u7f8e\u56fd\u56fd\u5bb6\u6838\u5b89\u5168\u59d4\u5458\u4f1a\u7684\u89c4\u5b9a\uff0c\u5bf9\u4e8e\u7b26\u5408NBIC\u89c4\u8303\u7684\u627f\u538b\u90e8\u4ef6\u7684\u7ef4\u4fee\u548c\u6539\u9020\uff0c\u5fc5\u987b\u52a0\u76d6R\u94a2\u5370\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u9a8c\u8bc1\u901a\u5e38\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u627e\u5230\u539f\u59cb\u94ed\u724c\u6570\u636e\uff0c\u5305\u62ec U \u94a2\u5370\u3001\u56fd\u5bb6\u9505\u7089\u68c0\u9a8c\u59d4\u5458\u4f1a\u7f16\u53f7\u3001\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u548c\u8bbe\u8ba1\u6e29\u5ea6\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6536\u96c6\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\u4ee5\u53ca\u4efb\u4f55\u540e\u7eed\u7ef4\u4fee\u6216\u6539\u88c5\u6587\u4ef6\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8fdb\u884c\u65e0\u635f\u68c0\u6d4b\uff08NDE\uff09\u548c\u76ee\u89c6\u68c0\u67e5\uff0c\u4ee5\u786e\u8ba4\u5269\u4f59\u58c1\u539a\u548c\u7ed3\u6784\u5b8c\u6574\u6027\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6839\u636e\u6d4b\u91cf\u6761\u4ef6\u8fdb\u884c\u518d\u8ba4\u8bc1\u5de5\u7a0b\u5206\u6790\uff0c\u4ee5\u9a8c\u8bc1\u5f53\u524d\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u5f53\u539f\u59cb\u6587\u4ef6\u4e0d\u5b8c\u6574\u65f6\uff0c\u64cd\u4f5c\u4eba\u5458\u5e94\u53c2\u8003\u56fd\u5bb6\u9505\u7089\u53ca\u538b\u529b\u5bb9\u5668\u68c0\u9a8c\u59d4\u5458\u4f1a\uff08National Board\uff09\u7684\u8bb0\u5f55\uff0c\u4ee5\u786e\u8ba4\u627f\u538b\u90e8\u4ef6\u7684\u5efa\u9020\u7b26\u5408\u7f8e\u56fd\u673a\u68b0\u5de5\u7a0b\u5e08\u534f\u4f1a\uff08ASME\uff09\u89c4\u8303\u3002\u5bf9\u4e8e\u8de8\u591a\u4e2a\u53f8\u6cd5\u7ba1\u8f96\u533a\u8fd0\u884c\u7684\u53cd\u5e94\u5806\uff0c\u5176\u4ed6\u7b49\u6548\u6807\u51c6\uff0c\u4f8b\u5982\u6b27\u76df\u538b\u529b\u8bbe\u5907\u6307\u4ee4\uff08PED\uff092014\/68\/EU\u3001EN 13445\u3001CE\u6807\u5fd7\u4ee5\u53ca\u82f1\u56fdPSSR 2000\uff0c\u4e5f\u53ef\u80fd\u9002\u7528\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5728\u786e\u5b9a\u4e86\u5408\u89c4\u6027\u9a8c\u8bc1\u4e4b\u540e\uff0c\u4e0b\u4e00\u4e2a\u9700\u8981\u8003\u8651\u7684\u95ee\u9898\u662f\uff0c\u5f53\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u4e0e\u5f53\u524d\u7684 ASME \u8981\u6c42\u4e0d\u4e00\u81f4\u65f6\uff0c\u4f1a\u9762\u4e34\u54ea\u4e9b\u5e38\u89c1\u6311\u6218\u3002.<\/span><\/p>\n<h2><b>\u5c06\u53cd\u5e94\u5806\u538b\u529b\u989d\u5b9a\u503c\u4e0e ASME \u8981\u6c42\u76f8\u5339\u914d\u65f6\uff0c\u5e38\u89c1\u7684\u6311\u6218\u6709\u54ea\u4e9b\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u5c06\u53cd\u5e94\u5806\u538b\u529b\u989d\u5b9a\u503c\u4e0e ASME \u8981\u6c42\u5339\u914d\u65f6\uff0c\u5e38\u89c1\u7684\u6311\u6218\u5305\u62ec\u710a\u63a5\u6587\u6863\u7f3a\u5931\u3001\u7f3a\u5c11\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\u4ee5\u53ca\u538b\u529b\u5386\u53f2\u8bb0\u5f55\u672a\u77e5\u3002\u4ee5\u4e0b\u5404\u5c0f\u8282\u5c06\u63a2\u8ba8\u6587\u6863\u5408\u89c4\u6027\u65b9\u9762\u7684\u4e0d\u8db3\uff0c\u4ee5\u53ca\u5982\u4f55\u5904\u7406 ASME \u72b6\u6001\u672a\u77e5\u7684\u53cd\u5e94\u5806\u3002.<\/span><\/p>\n<h3><b>\u8fd0\u8425\u5546\u5982\u4f55\u89e3\u51b3\u6587\u6863\u6216\u4ee3\u7801\u5408\u89c4\u6027\u65b9\u9762\u7684\u4e0d\u8db3\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u64cd\u4f5c\u4eba\u5458\u53ef\u4ee5\u901a\u8fc7\u91cd\u5efa\u710a\u63a5\u8bb0\u5f55\u3001\u8fdb\u884c\u5de5\u7a0b\u5206\u6790\u4ee5\u53ca\u8058\u8bf7\u6388\u6743\u68c0\u9a8c\u5458\u9a8c\u8bc1\u8239\u8236\u5f53\u524d\u72b6\u51b5\u6765\u5f25\u8865\u6587\u4ef6\u6216\u89c4\u8303\u5408\u89c4\u6027\u65b9\u9762\u7684\u4e0d\u8db3\u3002ASME \u7b2c IX \u5377\u8981\u6c42\u6bcf\u6761\u7b26\u5408\u89c4\u8303\u7684\u710a\u7f1d\u90fd\u5fc5\u987b\u6709\u4e66\u9762\u7684\u710a\u63a5\u5de5\u827a\u89c4\u7a0b (WPS) \u548c\u5de5\u827a\u8bc4\u5b9a\u8bb0\u5f55 (PQR)\u3002\u5982\u679c\u7f3a\u5c11\u8fd9\u4e9b\u6587\u4ef6\uff0c\u64cd\u4f5c\u4eba\u5458\u5fc5\u987b\u901a\u8fc7\u65b0\u7684\u6d4b\u8bd5\u5bf9\u710a\u7f1d\u8fdb\u884c\u91cd\u65b0\u8bc4\u5b9a\uff0c\u6216\u83b7\u53d6\u5176\u4ed6\u8bc1\u636e\u8bc1\u660e\u539f\u59cb\u5236\u9020\u7b26\u5408\u89c4\u8303\u8981\u6c42\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5f25\u5408\u5408\u89c4\u5dee\u8ddd\u7684\u5207\u5b9e\u6b65\u9aa4\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u4ece\u5236\u9020\u8bb0\u5f55\u6216\u56fd\u5bb6\u59d4\u5458\u4f1a\u6863\u6848\u4e2d\u67e5\u627e\u539f\u59cb\u7684 U-1 \u6216 U-1A \u5236\u9020\u5546\u6570\u636e\u62a5\u544a\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6839\u636e API 579-1\/ASME FFS-1 \u8fdb\u884c\u9002\u7528\u6027\u8bc4\u4f30\uff0c\u4ee5\u8bc4\u4f30\u5f53\u524d\u7684\u5b8c\u6574\u6027\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8fdb\u884c\u65e0\u635f\u68c0\u6d4b\uff08NDE\uff09\uff0c\u4f8b\u5982\u8d85\u58f0\u6ce2\u6d4b\u539a\u3001\u5c04\u7ebf\u7167\u76f8\u6216\u78c1\u7c89\u68c0\u6d4b\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8058\u8bf7\u6301\u6709 R \u8ba4\u8bc1\u6807\u5fd7\u7684\u627f\u5305\u5546\u8fdb\u884c\u4efb\u4f55\u5fc5\u8981\u7684\u7ef4\u4fee\u6216\u6539\u9020\uff0c\u4ee5\u6062\u590d\u7b26\u5408\u89c4\u8303\u7684\u8981\u6c42\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u5bf9\u4e8e\u4f9d\u636e\u6b27\u76df\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU \u6216\u82f1\u56fd\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6761\u4f8b (PSSR) \u8fd0\u884c\u7684\u53cd\u5e94\u5806\uff0c\u9002\u7528\u7c7b\u4f3c\u7684\u6587\u6863\u8981\u6c42\u3002\u5728\u8d2d\u7f6e\u6216\u91cd\u65b0\u90e8\u7f72\u4e4b\u524d\u8fdb\u884c\u4e3b\u52a8\u7684\u5dee\u8ddd\u5206\u6790\uff0c\u53ef\u4ee5\u907f\u514d\u4ee3\u4ef7\u9ad8\u6602\u7684\u5408\u89c4\u6027\u95ee\u9898\u3002.<\/span><\/p>\n<h3><b>\u5982\u679c\u53cd\u5e94\u5806\u7684\u538b\u529b\u7b49\u7ea7\u6216 ASME \u8ba4\u8bc1\u72b6\u6001\u672a\u77e5\uff0c\u4f1a\u53d1\u751f\u4ec0\u4e48\u60c5\u51b5\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u5982\u679c\u53cd\u5e94\u5806\u7684\u538b\u529b\u7b49\u7ea7\u6216ASME\u8ba4\u8bc1\u72b6\u6001\u672a\u77e5\uff0c\u5219\u5728\u6295\u5165\u4f7f\u7528\u524d\u5fc5\u987b\u8fdb\u884c\u5f3a\u5236\u6027\u5de5\u7a0b\u8bc4\u4f30\u3002\u6ca1\u6709\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u6587\u4ef6\uff0c\u53cd\u5e94\u5806\u4e0d\u80fd\u5408\u6cd5\u5730\u4f7f\u7528ASME\u8ba4\u8bc1\u6807\u5fd7\uff0c\u800c\u4e14\u5927\u591a\u6570\u53f8\u6cd5\u7ba1\u8f96\u533a\u7981\u6b62\u8fd0\u884c\u672a\u7ecf\u6ce8\u518c\u7684\u538b\u529b\u5bb9\u5668\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5178\u578b\u7684\u89e3\u51b3\u8def\u5f84\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8fdb\u884c\u5f7b\u5e95\u7684\u76ee\u89c6\u548c\u5c3a\u5bf8\u68c0\u67e5\uff0c\u4ee5\u786e\u5b9a\u94ed\u724c\u6570\u636e\u3001\u6750\u6599\u7b49\u7ea7\u548c\u6784\u9020\u7ec6\u8282\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6839\u636e\u6d4b\u91cf\u7684\u58c1\u539a\u3001\u786e\u5b9a\u7684\u6750\u6599\u7279\u6027\u548c\u8150\u8680\u88d5\u91cf\u8fdb\u884c\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u8ba1\u7b97\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u5b8c\u6210\u81f3\u5c11 1.3 \u500d\u8ba1\u7b97 MAWP \u7684\u6c34\u538b\u8bd5\u9a8c\uff0c\u4ee5\u9a8c\u8bc1\u538b\u529b\u5b8c\u6574\u6027\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u83b7\u5f97\u6388\u6743\u68c0\u9a8c\u5458\u7684\u5ba1\u67e5\uff0c\u4ee5\u9a8c\u8bc1\u8239\u8236\u662f\u5426\u7b26\u5408 ASME \u7b2c VIII \u5377\u7684\u91cd\u65b0\u8bc4\u7ea7\u6216\u6ce8\u518c\u8981\u6c42\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u6839\u636eTT\u4ff1\u4e50\u90e82025\u5e74\u7684\u884c\u4e1a\u98ce\u9669\u8bc4\u4f30\uff0c\u4e0d\u9075\u5b88ASME\u6216EN\u7b49\u516c\u8ba4\u89c4\u8303\u53ef\u80fd\u4f1a\u5bfc\u81f4\u5de5\u4e1a\u4fdd\u9669\u5728\u53d1\u751f\u4e8b\u6545\u65f6\u5931\u6548\u3002\u8fd9\u79cd\u8d22\u52a1\u98ce\u9669\u4f7f\u5f97\u8fdb\u884c\u9002\u5f53\u7684\u8bc4\u4f30\u81f3\u5173\u91cd\u8981\uff0c\u800c\u975e\u53ef\u6709\u53ef\u65e0\u3002\u5bf9\u4e8e\u91c7\u8d2d\u56e2\u961f\u800c\u8a00\uff0c\u91c7\u8d2d\u4e8c\u624b\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u524d\u786e\u8ba4\u5176\u662f\u5426\u7b26\u5408ASME\u6807\u51c6\u53ef\u4ee5\u907f\u514d\u540e\u7eed\u8d23\u4efb\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5728\u786e\u5b9a\u4e86\u5408\u89c4\u6027\u6311\u6218\u4e4b\u540e\uff0c\u6750\u6599\u7684\u9009\u62e9\u4f1a\u8fdb\u4e00\u6b65\u5f71\u54cd\u538b\u529b\u7b49\u7ea7\u4e0e\u89c4\u8303\u8981\u6c42\u7684\u4e00\u81f4\u6027\u3002.<\/span><\/p>\n<h2><b>\u6750\u6599\u9009\u62e9\u5982\u4f55\u5f71\u54cd\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548cASME\u5408\u89c4\u6027\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u6750\u6599\u7684\u9009\u62e9\u4f1a\u5f71\u54cd\u53cd\u5e94\u5806\u7684\u538b\u529b\u7b49\u7ea7\u548cASME\u89c4\u8303\u7684\u7b26\u5408\u6027\uff0c\u56e0\u4e3a\u5b83\u51b3\u5b9a\u4e86\u5141\u8bb8\u5e94\u529b\u503c\u3001\u8010\u8150\u8680\u6027\u548c\u6700\u9ad8\u5de5\u4f5c\u6e29\u5ea6\u3002\u4ee5\u4e0b\u5404\u5c0f\u8282\u5c06\u9610\u8ff0\u642a\u73bb\u7483\u53cd\u5e94\u5806\u548c\u5408\u91d1\u53cd\u5e94\u5806\u5728\u538b\u529b\u8003\u8651\u56e0\u7d20\u4e0a\u7684\u5dee\u5f02\uff0c\u4ee5\u53ca\u54ea\u4e9b\u6d4b\u8bd5\u65b9\u6cd5\u53ef\u4ee5\u9a8c\u8bc1\u6750\u6599\u7684\u5b8c\u6574\u6027\u3002.<\/span><\/p>\n<h3><b>\u4e3a\u4ec0\u4e48\u642a\u73bb\u7483\u53cd\u5e94\u5668\u548c\u5408\u91d1\u53cd\u5e94\u5668\u7684\u538b\u529b\u7b49\u7ea7\u8981\u6c42\u4e0d\u540c\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u642a\u73bb\u7483\u53cd\u5e94\u5668\u548c\u5408\u91d1\u53cd\u5e94\u5668\u7684\u538b\u529b\u7b49\u7ea7\u8003\u8651\u56e0\u7d20\u4e0d\u540c\uff0c\u56e0\u4e3a\u5b83\u4eec\u7684\u6750\u6599\u7279\u6027\u5728\u538b\u529b\u548c\u6e29\u5ea6\u4e0b\u5bf9\u5176\u673a\u68b0\u6027\u80fd\u6709\u7740\u4e0d\u540c\u7684\u9650\u5236\u3002\u642a\u73bb\u7483\u53cd\u5e94\u5668\u4f9d\u9760\u4e00\u5c42\u8106\u6027\u6d82\u5c42\u4e0e\u78b3\u94a2\u57fa\u6750\u7ed3\u5408\uff1b\u70ed\u51b2\u51fb\u6216\u8fc7\u9ad8\u7684\u538b\u529b\u4f1a\u5bfc\u81f4\u6d82\u5c42\u7834\u88c2\uff0c\u56e0\u6b64\u8bbe\u8ba1\u538b\u529b\u8f83\u4e3a\u4fdd\u5b88\u3002\u5408\u91d1\u53cd\u5e94\u5668\u91c7\u7528\u54c8\u6c0f\u5408\u91d1C-276\u6216316L\u4e0d\u9508\u94a2\u7b49\u6750\u6599\u5236\u6210\uff0c\u80fd\u591f\u627f\u53d7\u66f4\u9ad8\u7684\u5141\u8bb8\u5e94\u529b\u3002\u636eSJZ Metalsin Tech\u516c\u53f8\u79f0\uff0c\u54c8\u6c0f\u5408\u91d1C-276\u5728100\u00b0F (38\u00b0C)\u4e0b\u7684\u6700\u5927\u5141\u8bb8\u5e94\u529b\u4e3a27.3 ksi\uff0c\u57281,000\u00b0F (538\u00b0C)\u4e0b\u5219\u964d\u81f322.3 ksi\u3002\u8150\u8680\u88d5\u91cf\u8981\u6c42\u4e5f\u4e0d\u540c\uff1a\u78b3\u94a2\u5bb9\u5668\u7684\u5e38\u89c1\u9644\u52a0\u503c\u8303\u56f4\u4e3a1\/16\u82f1\u5bf8\uff081.5\u6beb\u7c73\uff09\u81f31\/8\u82f1\u5bf8\uff083\u6beb\u7c73\uff09\uff0c\u5177\u4f53\u53d6\u51b3\u4e8e\u4f7f\u7528\u73af\u5883\u7684\u4e25\u82db\u7a0b\u5ea6\uff0c\u800c\u9ad8\u5408\u91d1\u6750\u6599\u901a\u5e38\u53ea\u9700\u8981\u6781\u5c11\u7684\u8150\u8680\u88d5\u91cf\u6216\u65e0\u9700\u8150\u8680\u88d5\u91cf\u3002.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-6984 size-large\" src=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-1024x572.jpg\" alt=\"\u5728\u6d01\u51c0\u7684\u751f\u4ea7\u8f66\u95f4\u91cc\uff0c\u4e0d\u9508\u94a2\u5de5\u4e1a\u53cd\u5e94\u91dc\u6446\u653e\u5728\u4e00\u4e2a\u655e\u5f00\u7684\u73bb\u7483\u5185\u886c\u7f50\u65c1\u8fb9\u3002.\" width=\"1024\" height=\"572\" srcset=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-18x10.jpg 18w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-200x112.jpg 200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-300x167.jpg 300w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-400x223.jpg 400w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-600x335.jpg 600w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-768x429.jpg 768w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-800x447.jpg 800w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-1024x572.jpg 1024w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison-1200x670.jpg 1200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/glass-lined-versus-alloy-reactor-material-comparison.jpg 1376w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h3><b>\u54ea\u4e9b\u6d4b\u8bd5\u65b9\u6cd5\u53ef\u4ee5\u9a8c\u8bc1\u6750\u6599\u5b8c\u6574\u6027\u662f\u5426\u7b26\u5408ASME\u6807\u51c6\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u4e3a\u786e\u4fdd\u6750\u6599\u7b26\u5408ASME\u6807\u51c6\uff0c\u9a8c\u8bc1\u6750\u6599\u5b8c\u6574\u6027\u7684\u6d4b\u8bd5\u65b9\u6cd5\u5305\u62ec\u6c34\u538b\u8bd5\u9a8c\u3001\u65e0\u635f\u68c0\u6d4b (NDE) \u548c\u6750\u6599\u53ef\u8ffd\u6eaf\u6027\u8bb0\u5f55\u3002\u6839\u636eASME\u7b2c\u516b\u5377UG-99\u6761\u89c4\u5b9a\uff0c\u6c34\u538b\u8bd5\u9a8c\u662f\u89c4\u8303\u8ba4\u8bc1\u524d\u7684\u5f3a\u5236\u6027\u8981\u6c42\u3002\u6807\u51c6\u6c34\u538b\u8bd5\u9a8c\u538b\u529b\u5fc5\u987b\u8fbe\u5230\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP) \u7684\u81f3\u5c111.3\u500d\uff0c\u5e76\u6839\u636e\u8bd5\u9a8c\u6e29\u5ea6\u4e0e\u8bbe\u8ba1\u6e29\u5ea6\u4e4b\u95f4\u7684\u5e94\u529b\u6bd4\u8fdb\u884c\u4fee\u6b63\u3002\u5176\u4ed6\u65e0\u635f\u68c0\u6d4b\u6280\u672f\uff0c\u4f8b\u5982\u8d85\u58f0\u6ce2\u6d4b\u539a\u3001\u5c04\u7ebf\u7167\u76f8\u68c0\u6d4b\u548c\u78c1\u7c89\u63a2\u4f24\uff0c\u7528\u4e8e\u786e\u8ba4\u710a\u7f1d\u548c\u6bcd\u6750\u6ee1\u8db3\u6240\u9700\u7684\u5b8c\u6574\u6027\u9608\u503c\uff0c\u4e14\u4e0d\u4f1a\u5bf9\u5bb9\u5668\u9020\u6210\u635f\u574f\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5bf9\u4e8e\u8de8\u8d8a\u7ba1\u8f96\u8fb9\u754c\u7684\u53cd\u5e94\u5806\uff0c\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU\u3001EN 13445 \u548c\u82f1\u56fd 2000 \u5e74\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6cd5\u89c4 (PSSR) \u7b49\u7b49\u6548\u6807\u51c6\u89c4\u5b9a\u4e86\u7c7b\u4f3c\u7684\u6750\u6599\u9a8c\u8bc1\u8981\u6c42\uff0c\u5305\u62ec CE \u6807\u5fd7\u6216 UKCA \u6807\u5fd7\u6587\u4ef6\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u4e86\u89e3\u6750\u6599\u7279\u5b9a\u7684\u538b\u529b\u9650\u5236\u53ef\u4ee5\u7b80\u5316\u91c7\u8d2d\u6216\u91cd\u65b0\u90e8\u7f72\u4e8c\u624b\u53cd\u5e94\u5806\u8bbe\u5907\u65f6\u7684\u5408\u89c4\u6027\u3002.<\/span><\/p>\n<h2><b>ASME \u5408\u89c4\u6027\u5982\u4f55\u5f71\u54cd\u53cd\u5e94\u5806\u7684\u8f6c\u552e\u3001\u7ffb\u65b0\u6216\u91cd\u65b0\u90e8\u7f72\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">ASME\u89c4\u8303\u7684\u5408\u89c4\u6027\u4f1a\u5f71\u54cd\u53cd\u5e94\u5806\u7684\u8f6c\u552e\u3001\u7ffb\u65b0\u6216\u91cd\u65b0\u90e8\u7f72\uff0c\u56e0\u4e3a\u5b83\u51b3\u5b9a\u4e86\u53cd\u5e94\u5806\u80fd\u5426\u5408\u6cd5\u8f6c\u8ba9\u6240\u6709\u6743\u3001\u8fdb\u884c\u6539\u9020\u6216\u5728\u65b0\u7684\u53f8\u6cd5\u7ba1\u8f96\u533a\u8fd0\u884c\u3002\u4ee5\u4e0b\u5404\u5c0f\u8282\u5c06\u4ecb\u7ecd\u4ea4\u6613\u6240\u9700\u7684\u6587\u6863\u4ee5\u53ca\u5347\u7ea7\u6539\u9020\u5982\u4f55\u5f71\u54cd\u6301\u7eed\u7684\u89c4\u8303\u9075\u5b88\u60c5\u51b5\u3002.<\/span><\/p>\n<h3><b>\u8d2d\u4e70\u6216\u51fa\u552e\u4e8c\u624bASME\u8ba4\u8bc1\u53cd\u5e94\u5806\u65f6\u9700\u8981\u54ea\u4e9b\u6587\u4ef6\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u8d2d\u4e70\u6216\u51fa\u552e\u4e8c\u624bASME\u8ba4\u8bc1\u53cd\u5e94\u5806\u65f6\u6240\u9700\u7684\u6587\u4ef6\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u539f\u59cb\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\uff08U-1 \u8868\u683c\u6216\u5355\u5ba4\u5bb9\u5668\u7684 U-1A \u8868\u683c\uff09\uff0c\u8bc1\u5b9e\u8be5\u5bb9\u5668\u662f\u6309\u7167 ASME BPVC \u7b2c VIII \u8282\u5efa\u9020\u7684\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u56fd\u5bb6\u9505\u7089\u68c0\u9a8c\u5c40\u6ce8\u518c\u53f7\u548c\u94ed\u724c\u6570\u636e\uff0c\u8bc1\u5b9e\u5176\u7b26\u5408\u7f8e\u56fd\u673a\u68b0\u5de5\u7a0b\u5e08\u534f\u4f1a\uff08ASME\uff09\u89c4\u8303\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6c34\u538b\u8bd5\u9a8c\u8bb0\u5f55\u8868\u660e\uff0c\u5728\u81f3\u5c11 1.3 \u500d\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b\u4e0b\uff0c\u538b\u529b\u5b8c\u6574\u6027\u826f\u597d\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6839\u636e ASME \u7b2c IX \u8282\u5236\u5b9a\u710a\u63a5\u5de5\u827a\u89c4\u7a0b (WPS) \u548c\u5de5\u827a\u8bc4\u5b9a\u8bb0\u5f55 (PQR)\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u7ef4\u62a4\u548c\u68c0\u67e5\u5386\u53f2\u8bb0\u5f55\uff0c\u5305\u62ec\u6839\u636e\u56fd\u5bb6\u68c0\u9a8c\u89c4\u8303 (NBIC) \u8fdb\u884c\u7684\u4efb\u4f55 R \u6807\u8bb0\u7ef4\u4fee\u6216\u6539\u88c5\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u6839\u636eTT Club\u53d1\u5e03\u7684\u300a2025\u5e74\u5c55\u671b\u62a5\u544a\u300b\uff0c\u5982\u679c\u6ca1\u6709\u8fd9\u4e9b\u8bb0\u5f55\uff0c\u4e0d\u7b26\u5408ASME\u6216EN\u7b49\u516c\u8ba4\u89c4\u8303\u53ef\u80fd\u4f1a\u5bfc\u81f4\u5de5\u4e1a\u4fdd\u9669\u5728\u53d1\u751f\u4e8b\u6545\u65f6\u5931\u6548\u3002\u5bf9\u4e8e\u8bc4\u4f30\u4e8c\u624b\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u7684\u91c7\u8d2d\u5de5\u7a0b\u5e08\u800c\u8a00\uff0c\u7f3a\u5c11\u6587\u6863\u5f80\u5f80\u662f\u91cd\u65b0\u90e8\u7f72\u7684\u6700\u5927\u969c\u788d\u3002.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6985 size-large\" src=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-1024x572.jpg\" alt=\"\u529e\u516c\u684c\u4e0a\u6446\u653e\u7740\u6574\u7406\u597d\u7684\u6280\u672f\u6587\u6863\u6587\u4ef6\u5939\u3001\u5de5\u7a0b\u56fe\u7eb8\u3001\u5199\u5b57\u677f\u3001\u7b14\u548c\u773c\u955c\u3002.\" width=\"1024\" height=\"572\" srcset=\"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-18x10.jpg 18w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-200x112.jpg 200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-300x167.jpg 300w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-400x223.jpg 400w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-600x335.jpg 600w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-768x429.jpg 768w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-800x447.jpg 800w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-1024x572.jpg 1024w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance-1200x670.jpg 1200w, https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/pressure-vessel-documentation-package-resale-compliance.jpg 1376w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h3><b>\u7ffb\u65b0\u548c\u5347\u7ea7\u5982\u4f55\u5f71\u54cd\u6301\u7eed\u7684 ASME \u5408\u89c4\u6027\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u7ffb\u65b0\u548c\u5347\u7ea7\u4f1a\u5f71\u54cdASME\u5408\u89c4\u6027\uff0c\u56e0\u4e3a\u53ea\u8981\u627f\u538b\u90e8\u4ef6\u53d1\u751f\u6539\u52a8\uff0c\u5c31\u4f1a\u89e6\u53d1\u91cd\u65b0\u8ba4\u8bc1\u8981\u6c42\u3002\u6839\u636e\u7f8e\u56fd\u56fd\u5bb6\u9505\u7089\u68c0\u9a8c\u59d4\u5458\u4f1a\uff08NBIC\uff09\u7684\u89c4\u5b9a\uff0c\u4efb\u4f55\u5bf9\u627f\u538b\u90e8\u4ef6\u7684\u7ef4\u4fee\u6216\u6539\u52a8\u90fd\u9700\u8981R\u94a2\u5370\u6301\u6709\u4eba\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u91cd\u65b0\u8ba4\u8bc1\u6d41\u7a0b\u5305\u62ec\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6536\u96c6\u539f\u59cb\u8bbe\u8ba1\u6587\u4ef6\u5e76\u786e\u8ba4\u5f53\u524d\u58c1\u539a\u4e0b\u7684\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b (MAWP)\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8fdb\u884c\u65e0\u635f\u68c0\u6d4b\uff08NDE\uff09\u548c\u76ee\u89c6\u68c0\u67e5\uff0c\u4ee5\u9a8c\u8bc1\u5269\u4f59\u8150\u8680\u88d5\u91cf\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u901a\u8fc7\u5de5\u7a0b\u5206\u6790\u786e\u8ba4\u4fee\u6539\u540e\u7684\u5bb9\u5668\u4ecd\u7136\u7b26\u5408 ASME \u7b2c VIII \u5377\u7b2c 1 \u90e8\u5206\u6216\u7b2c 2 \u90e8\u5206\u7684\u89c4\u5b9a\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u53cd\u5e94\u5806\u6062\u590d\u8fd0\u884c\u524d\uff0c\u9700\u7ecf\u6388\u6743\u68c0\u67e5\u5458\u7b7e\u5b57\u786e\u8ba4\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">\u7f8e\u56fd\u4ee5\u5916\u7684\u53f8\u6cd5\u7ba1\u8f96\u533a\u4e5f\u89c4\u5b9a\u4e86\u7c7b\u4f3c\u7684\u4e49\u52a1\u3002\u6b27\u76df\u7684\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU\u3001\u82f1\u56fd\u7684\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6cd5\u89c4 (PSSR) 2000 \u4ee5\u53ca\u5fb7\u56fd\u7684\u4ea7\u54c1\u5b89\u5168\u6cd5 (ProdSG) \u5747\u8981\u6c42\u5728\u8bbe\u5907\u6539\u9020\u540e\u8fdb\u884c\u4e66\u9762\u68c0\u67e5\u548c\u5408\u89c4\u6027\u9a8c\u8bc1\u3002.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u5728\u8d2d\u4e70\u4e4b\u524d\u4e86\u89e3\u8fd9\u4e9b\u8981\u6c42\uff0c\u53ef\u4ee5\u7b80\u5316\u4ece\u91c7\u8d2d\u5230\u8fd0\u8425\u90e8\u7f72\u7684\u8def\u5f84\u3002.<\/span><\/p>\n<h2><b>\u5728\u4f7f\u7528\u56fd\u9645\u5de5\u827a\u88c5\u7f6e\u516c\u53f8\u7684\u5e93\u5b58\u548c\u89e3\u51b3\u65b9\u6848\u65f6\uff0c\u5e94\u8be5\u5982\u4f55\u8fdb\u884c\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u8bc4\u5b9a\u548c ASME \u5408\u89c4\u6027\u8bc4\u4f30\uff1f<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">\u60a8\u5e94\u8be5\u5229\u7528\u56fd\u9645\u5de5\u827a\u88c5\u7f6e\u516c\u53f8\u62e5\u6709\u7684\u5168\u65b0\u5269\u4f59\u548c\u4f18\u8d28\u4e8c\u624b\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u5e93\u5b58\uff0c\u6765\u786e\u5b9a\u53cd\u5e94\u5668\u7684\u538b\u529b\u7b49\u7ea7\u548c ASME \u5408\u89c4\u6027\u3002\u8fd9\u4e9b\u5e93\u5b58\u5305\u62ec\u7b26\u5408 ASME \u7b2c VIII \u5377\u548c\u56fd\u9645\u7b49\u6548\u6807\u51c6\uff08\u4f8b\u5982\u6b27\u76df\u538b\u529b\u8bbe\u5907\u6307\u4ee4 (PED) 2014\/68\/EU \u548c EN 13445\uff09\u7684\u5df2\u8bb0\u5f55\u4ee3\u7801\u6807\u8bb0\u7684\u5bb9\u5668\u3002.<\/span><\/p>\n<h3><b>\u56fd\u9645\u5de5\u827a\u88c5\u7f6e\u516c\u53f8\u7684\u5b50\u516c\u53f8\u80fd\u5426\u534f\u52a9\u91c7\u8d2d\u7b26\u5408 ASME \u6807\u51c6\u7684\u53cd\u5e94\u5668\u6216\u7cfb\u7edf\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u662f\u7684\uff0cInternational Process Plants \u7684\u5b50\u516c\u53f8\u53ef\u4ee5\u534f\u52a9\u60a8\u91c7\u8d2d\u7b26\u5408 ASME \u6807\u51c6\u7684\u53cd\u5e94\u5668\u548c\u7cfb\u7edf\u3002Universal Glasteel Equipment (UGE) \u4e13\u6ce8\u4e8e\u73bb\u7483\u548c\u642a\u73bb\u7483\u8bbe\u5907\uff0c\u800c Gale Process Solutions (GPS) \u5219\u4e13\u6ce8\u4e8e\u65b0\u578b\u5408\u91d1\u8bbe\u5907\u3002International Process Plants \u5728\u7f8e\u56fd\u5357\u5361\u7f57\u6765\u7eb3\u5dde\u3001\u5fb7\u56fd\u548c\u82f1\u56fd\u7684\u4ed3\u5e93\u4e2d\u62e5\u6709\u8d85\u8fc7 10,000 \u4ef6\u8bbe\u5907\u7684\u5e93\u5b58\uff0c\u5176\u4e2d\u5305\u62ec\u5927\u91cf\u7684\u53cd\u5e94\u5668\u5e93\u5b58\u3002\u6bcf\u53f0\u8bbe\u5907\u90fd\u5305\u542b\u76f8\u5173\u6587\u4ef6\uff0c\u4f8b\u5982\u5236\u9020\u5546\u6570\u636e\u62a5\u544a\u548c\u94ed\u724c\u6570\u636e\uff0c\u4ee5\u652f\u6301\u89c4\u8303\u7b26\u5408\u6027\u9a8c\u8bc1\u3002\u5bf9\u4e8e\u6839\u636e PED \u6216\u82f1\u56fd 2000 \u5e74\u538b\u529b\u7cfb\u7edf\u5b89\u5168\u6cd5\u89c4 (PSSR) \u8fd0\u884c\u7684\u8bbe\u65bd\uff0cInternational Process Plants \u76ee\u524d\u7684\u5e93\u5b58\u6db5\u76d6\u4e86\u9700\u8981 ASME \u94a2\u5370\u3001CE \u6807\u5fd7\u6216 UKCA \u6807\u5fd7\u7684\u5730\u533a\u3002.<\/span><\/p>\n<h3><b>\u6211\u4eec\u8ba8\u8bba\u7684\u5173\u4e8e\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548c ASME \u5408\u89c4\u6027\u7684\u4e3b\u8981\u5185\u5bb9\u6709\u54ea\u4e9b\uff1f<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">\u5173\u4e8e\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548cASME\u5408\u89c4\u6027\uff0c\u4ee5\u4e0b\u662f\u4e00\u4e9b\u5173\u952e\u8981\u70b9\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u8bbe\u8ba1\u538b\u529b\u3001MAWP \u548c\u538b\u529b\u7b49\u7ea7\u63cf\u8ff0\u7684\u662f\u540c\u4e00\u4e2a\u57fa\u672c\u6982\u5ff5\uff1a\u53cd\u5e94\u5806\u538b\u529b\u5bb9\u5668\u5728\u7ed9\u5b9a\u6e29\u5ea6\u4e0b\u7684\u6700\u5927\u5b89\u5168\u64cd\u4f5c\u8303\u56f4\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">ASME BPVC \u7b2c VIII \u90e8\u5206\u89c4\u8303\u4e86\u65bd\u5de5\uff1b\u5408\u89c4\u6027\u3001\u4e00\u81f4\u6027\u548c\u89c4\u8303\u9075\u5b88\u6027\u5747\u6307\u901a\u8fc7\u8ba4\u8bc1\u3001\u76d6\u7ae0\u548c\u56fd\u5bb6\u59d4\u5458\u4f1a\u6ce8\u518c\u6765\u6ee1\u8db3\u8fd9\u4e9b\u8981\u6c42\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u5728\u4efb\u4f55\u8239\u8236\u83b7\u5f97\u8ba4\u8bc1\u5370\u7ae0\u4e4b\u524d\uff0c\u90fd\u8981\u8fdb\u884c 1.3 \u500d\u6700\u5927\u5141\u8bb8\u5de5\u4f5c\u538b\u529b\u7684\u6c34\u538b\u8bd5\u9a8c\uff0c\u4ee5\u9a8c\u8bc1\u5176\u538b\u529b\u5b8c\u6574\u6027\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6750\u6599\u7684\u9009\u62e9\u76f4\u63a5\u5f71\u54cd\u5141\u8bb8\u5e94\u529b\u548c\u8150\u8680\u88d5\u91cf\uff0c\u8fdb\u800c\u51b3\u5b9a\u53ef\u8fbe\u5230\u7684\u538b\u529b\u7b49\u7ea7\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u6587\u4ef6\uff0c\u5305\u62ec U-1 \u8868\u683c\u3001WPS\/PQR \u8bb0\u5f55\u548c\u68c0\u67e5\u62a5\u544a\uff0c\u5bf9\u4e8e\u8f6c\u552e\u3001\u91cd\u65b0\u90e8\u7f72\u548c\u4fdd\u9669\u6709\u6548\u6027\u81f3\u5173\u91cd\u8981\u3002.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">\u56fd\u9645\u6807\u51c6\u5982 PED 2014\/68\/EU\u3001EN 13445 \u548c PSSR 2000 \u4e0e ASME \u4e00\u8d77\u9002\u7528\u4e8e\u5728\u5168\u7403\u53f8\u6cd5\u7ba1\u8f96\u533a\u8fd0\u8425\u7684\u8bbe\u65bd\u3002.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">International Process Plants \u901a\u8fc7\u63d0\u4f9b\u5177\u6709\u53ef\u8ffd\u6eaf\u5408\u89c4\u5386\u53f2\u7684\u95f4\u6b47\u5f0f\u53cd\u5e94\u5668\u7b80\u5316\u4e86\u8fd9\u4e00\u8fc7\u7a0b\uff0c\u4ece\u800c\u4e3a\u91c7\u8d2d\u5de5\u7a0b\u5e08\u8282\u7701\u4e86\u6570\u5468\u7684\u6587\u6863\u6062\u590d\u548c\u91cd\u65b0\u8ba4\u8bc1\u5de5\u4f5c\u3002.<\/span><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Reactor pressure rating is the maximum internal pressure a vessel  [&#8230;]<\/p>\n","protected":false},"author":4,"featured_media":6986,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-6880","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-process-equipment"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reactor Pressure Rating and Asme Compliance<\/title>\n<meta name=\"description\" content=\"Ensure safe and reliable operations with reactor pressure rating insights and ASME compliance standards. Learn pressure limits, design codes, safety requirements, and industry best practices for industrial reactors.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/internationalprocessplants.com\/zh\/\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548casme\u5408\u89c4\u6027\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reactor Pressure Rating and Asme Compliance\" \/>\n<meta property=\"og:description\" content=\"Ensure safe and reliable operations with reactor pressure rating insights and ASME compliance standards. Learn pressure limits, design codes, safety requirements, and industry best practices for industrial reactors.\" \/>\n<meta property=\"og:url\" content=\"http:\/\/internationalprocessplants.com\/zh\/\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548casme\u5408\u89c4\u6027\/\" \/>\n<meta property=\"og:site_name\" content=\"International Inventory of New &amp; Used Process Plants\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-19T23:28:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-16T18:22:02+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1376\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Scott Phillips\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"Scott Phillips\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#article\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/\"},\"author\":{\"name\":\"Scott Phillips\",\"@id\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/#\\\/schema\\\/person\\\/23bd528384fb8cd450ae6388719947c6\"},\"headline\":\"What is reactor pressure rating and how does it relate to ASME compliance?\",\"datePublished\":\"2026-05-19T23:28:37+00:00\",\"dateModified\":\"2026-06-16T18:22:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/\"},\"wordCount\":2866,\"commentCount\":0,\"image\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/internationalprocessplants.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg\",\"articleSection\":[\"Process Equipment\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/\",\"url\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/\",\"name\":\"Reactor Pressure Rating and Asme Compliance\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#primaryimage\"},\"image\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/internationalprocessplants.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg\",\"datePublished\":\"2026-05-19T23:28:37+00:00\",\"dateModified\":\"2026-06-16T18:22:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/#\\\/schema\\\/person\\\/23bd528384fb8cd450ae6388719947c6\"},\"description\":\"Ensure safe and reliable operations with reactor pressure rating insights and ASME compliance standards. Learn pressure limits, design codes, safety requirements, and industry best practices for industrial reactors.\",\"breadcrumb\":{\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#primaryimage\",\"url\":\"https:\\\/\\\/internationalprocessplants.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg\",\"contentUrl\":\"https:\\\/\\\/internationalprocessplants.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg\",\"width\":1376,\"height\":768},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\\\/\\\/internationalprocessplants.com\\\/zh\\\/reactor-pressure-rating-and-asme-compliance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/internationalprocessplants.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is reactor pressure rating and how does it relate to ASME compliance?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/#website\",\"url\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/\",\"name\":\"International Process Plants\",\"description\":\"International Process Plants (IPP) is a global buyer and seller of process plants in the pharmaceutical, petrochemical, industrial chemical, fine\\\/specialty chemical, agrichemical fertilizer, oil refining, polymers, artificial fibers, power generation, gas processing, food processing, paper, metals and alternative fuels industries.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/internationalprocessplants.com\\\/zh\\\/#\\\/schema\\\/person\\\/23bd528384fb8cd450ae6388719947c6\",\"name\":\"Scott Phillips\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g\",\"caption\":\"Scott Phillips\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548cASME\u5408\u89c4\u6027","description":"\u901a\u8fc7\u4e86\u89e3\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548c ASME \u5408\u89c4\u6807\u51c6\uff0c\u786e\u4fdd\u5b89\u5168\u53ef\u9760\u7684\u8fd0\u884c\u3002\u5b66\u4e60\u5de5\u4e1a\u53cd\u5e94\u5806\u7684\u538b\u529b\u9650\u5236\u3001\u8bbe\u8ba1\u89c4\u8303\u3001\u5b89\u5168\u8981\u6c42\u548c\u884c\u4e1a\u6700\u4f73\u5b9e\u8df5\u3002.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/internationalprocessplants.com\/zh\/\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548casme\u5408\u89c4\u6027\/","og_locale":"zh_CN","og_type":"article","og_title":"Reactor Pressure Rating and Asme Compliance","og_description":"Ensure safe and reliable operations with reactor pressure rating insights and ASME compliance standards. Learn pressure limits, design codes, safety requirements, and industry best practices for industrial reactors.","og_url":"http:\/\/internationalprocessplants.com\/zh\/\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548casme\u5408\u89c4\u6027\/","og_site_name":"International Inventory of New &amp; Used Process Plants","article_published_time":"2026-05-19T23:28:37+00:00","article_modified_time":"2026-06-16T18:22:02+00:00","og_image":[{"width":1376,"height":768,"url":"http:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg","type":"image\/jpeg"}],"author":"Scott Phillips","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"Scott Phillips","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"14 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#article","isPartOf":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/"},"author":{"name":"Scott Phillips","@id":"https:\/\/internationalprocessplants.com\/zh\/#\/schema\/person\/23bd528384fb8cd450ae6388719947c6"},"headline":"What is reactor pressure rating and how does it relate to ASME compliance?","datePublished":"2026-05-19T23:28:37+00:00","dateModified":"2026-06-16T18:22:02+00:00","mainEntityOfPage":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/"},"wordCount":2866,"commentCount":0,"image":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#primaryimage"},"thumbnailUrl":"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg","articleSection":["Process Equipment"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#respond"]}]},{"@type":"WebPage","@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/","url":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/","name":"\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548cASME\u5408\u89c4\u6027","isPartOf":{"@id":"https:\/\/internationalprocessplants.com\/zh\/#website"},"primaryImageOfPage":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#primaryimage"},"image":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#primaryimage"},"thumbnailUrl":"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg","datePublished":"2026-05-19T23:28:37+00:00","dateModified":"2026-06-16T18:22:02+00:00","author":{"@id":"https:\/\/internationalprocessplants.com\/zh\/#\/schema\/person\/23bd528384fb8cd450ae6388719947c6"},"description":"\u901a\u8fc7\u4e86\u89e3\u53cd\u5e94\u5806\u538b\u529b\u7b49\u7ea7\u548c ASME \u5408\u89c4\u6807\u51c6\uff0c\u786e\u4fdd\u5b89\u5168\u53ef\u9760\u7684\u8fd0\u884c\u3002\u5b66\u4e60\u5de5\u4e1a\u53cd\u5e94\u5806\u7684\u538b\u529b\u9650\u5236\u3001\u8bbe\u8ba1\u89c4\u8303\u3001\u5b89\u5168\u8981\u6c42\u548c\u884c\u4e1a\u6700\u4f73\u5b9e\u8df5\u3002.","breadcrumb":{"@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#primaryimage","url":"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg","contentUrl":"https:\/\/internationalprocessplants.com\/wp-content\/uploads\/2026\/05\/industrial-pressure-vessel-manufacturing-facility-asme-compliance.jpg","width":1376,"height":768},{"@type":"BreadcrumbList","@id":"http:\/\/internationalprocessplants.com\/zh\/reactor-pressure-rating-and-asme-compliance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/internationalprocessplants.com\/"},{"@type":"ListItem","position":2,"name":"What is reactor pressure rating and how does it relate to ASME compliance?"}]},{"@type":"WebSite","@id":"https:\/\/internationalprocessplants.com\/zh\/#website","url":"https:\/\/internationalprocessplants.com\/zh\/","name":"\u56fd\u9645\u5de5\u827a\u5382","description":"\u56fd\u9645\u8fc7\u7a0b\u5de5\u5382 (IPP) \u662f\u5236\u836f\u3001\u77f3\u5316\u3001\u5de5\u4e1a\u5316\u5b66\u54c1\u3001\u7cbe\u7ec6\/\u7279\u79cd\u5316\u5b66\u54c1\u3001\u519c\u7528\u5316\u5b66\u54c1\/\u5316\u80a5\u3001\u77f3\u6cb9\u7cbe\u70bc\u3001\u805a\u5408\u7269\u3001\u4eba\u9020\u7ea4\u7ef4\u3001\u53d1\u7535\u3001\u5929\u7136\u6c14\u52a0\u5de5\u3001\u98df\u54c1\u52a0\u5de5\u3001\u9020\u7eb8\u3001\u91d1\u5c5e\u548c\u66ff\u4ee3\u71c3\u6599\u884c\u4e1a\u8fc7\u7a0b\u5de5\u5382\u7684\u5168\u7403\u4e70\u5bb6\u548c\u5356\u5bb6\u3002","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/internationalprocessplants.com\/zh\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Person","@id":"https:\/\/internationalprocessplants.com\/zh\/#\/schema\/person\/23bd528384fb8cd450ae6388719947c6","name":"\u65af\u79d1\u7279\u00b7\u83f2\u5229\u666e\u65af","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/secure.gravatar.com\/avatar\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0a7231a6a882261790ee79fc13d0cce47d15847f06d2db39331991315cb9cdc7?s=96&d=mm&r=g","caption":"Scott Phillips"}}]}},"_links":{"self":[{"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/posts\/6880","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/comments?post=6880"}],"version-history":[{"count":0,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/posts\/6880\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/media\/6986"}],"wp:attachment":[{"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/media?parent=6880"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/categories?post=6880"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/internationalprocessplants.com\/zh\/wp-json\/wp\/v2\/tags?post=6880"}],"curies":[{"name":"\u53ef\u6e7f\u6027\u7c89\u5242","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}